<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>16010</ErrorNumber>
<ErrorFamily>Image</ErrorFamily>
<ErrorMessage>
IMAGE: Total mainscan shift too large
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The net mainscan shift is calculated from the following parameters:
</text></DescriptionText>
<DescriptionText><NumberedList>
<ListItem><Text>"set gc mss" - nominal shift, the same for all recorders of the same model</Text></ListItem>
<ListItem><Text>"set gc mssa" - adjustment made during integration</Text></ListItem>
<ListItem><Text>"set mode &lt;mode&gt; mssa" - the workstation can overwrite this shift with a new one for each image</Text></ListItem>
</NumberedList></DescriptionText>
<DescriptionText><text>
The values of the "gc" parameters should be compared to the factory settings.  If these settings are not the
problem, the workstation must have sent a large positive mainscan shift.  This should be found and
adjusted.
</text></DescriptionText>
<DescriptionText><text>
The maximum mainscan shift is equal to 4096 pixels, i.e. 2.56 inches in 1600 DPI, 1.7 inches in 2400 DPI,
and 1.28 inches in 3200 DPI.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Record error message and contact Creo Service
</text></DescriptionText>
</OperatorAction>
<Cause>
"set gc mss", "set gc mssa", and/or "set mode &lt;mode&gt; mssa" shift parameters are incorrect
</Cause>
<Cause>
Workstation is specifying a large positive shift around the drum.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/gc_cfg_mss.xml</LinkAddress><LinkTitle>NVS: gc mss</LinkTitle></Link>
<Link><LinkAddress>../nvs/gc_cal_mssa.xml</LinkAddress><LinkTitle>NVS: gc mssa</LinkTitle></Link>
<Link><LinkAddress>../nvs/mode_cal_mssa.xml</LinkAddress><LinkTitle>NVS: mode mssa</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:27 2008 PST
</Updated>
<Links>
</Links>
</Error>